These MACE Doppler ultrasonic flow sensors are compatible with the Mace AgriFlo, FloPro and HVFlo ultrasonic flow meters.
 |
Strap Mount (Velocity Only) Sensor
This sensor is used to measure velocity in full pipes when access to the pipe is available and the pipe can be emptied when installation or maintenance is required. It can also be used in situations where the user is measuring depth by a third party or ultrasonic sensor. The sensor is first mounted on a polypropylene mounting strap and then installed within the pipe.
Material type: P.V.C.
Pipe sizes: 150mm (6") to 2000mm (79")
Dimensions: 125mm (5") L x 50mm (2") W x 16mm (0.62") H
|
 |
Strap Mount Velocity/Depth Sensor
This type of sensor is used in open channels or pipes that run partially full. This sensor is used to measure depth (using a capacitive pressure diaphragm) and velocity. Access to the monitoring point is required for installation and maintenance. The sensor is first mounted on a polypropylene mounting plate and then installed within the pipe or channel..
Depth Sensor
This type of sensor is a depth only strap mount sensor that is typically used to
measure the depth of a surcharge event in a sewer system manhole or depth over a weir or flume.
Material type: P.V.C.
Pipe sizes: 150mm (6") to 2000mm (79")
Dimensions: 125mm (5") L x 50mm (2") W x 16mm (0.62") H
Depth range: 4m (158"), 10m (394")
|
 |
Insert Sensor (Velocity Only)
Insertion sensors require access to the outside wall of the pipe in which the sensor is to be mounted. These sensors can be installed through a 2 inch ball valve or just through a 2 inch female thread fitting.
Material type: Nickel plated Brass (standard), 316 Stainless Steel (optional)
Thread type: Either 2" BSP or 2" NPT
Pipe sizes: 100mm (4") to 2000mm (79")
Dimensions: 355mm (14") L x 45mm (1.8") dia. x 25mm (1") H
|
|
|